Part Number Hot Search : 
S3C7434 W14902 W14902 M6800 C68HC70 C5030F0 A6812EEP TSP140B
Product Description
Full Text Search
 

To Download F2M01SXA-S01-B Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
Features
* * * * * * * * * * * * * Provides transparent RS-232 serial cable replacement. No need for external drivers. Power is supplied via the D-SUB or mini-USB connector. Supports the following Bluetooth(R) profiles: SPP, DUN, GAP, HCI. Interoperability with PDA, laptops etc. Range up to 300 m (line of sight). Configurable serial settings. Easy to use Configuration software available. Small size 36x17x60 (WxHxL) mm. High supply voltage range 5-30V DC. Simple pairing with onboard button. Led indications for power, data and status monitoring. Additional RS-232 lines for enhanced signaling.
F2M01SXA
Applications
The F2M01SXA Serial Port Plug can be connected to applications that currently use cables for serial communication. The F2M01SXA is also ideal if you are looking for a reliable and robust wireless link between any RS-232 enabled devices. The Ad-Hoc connectivity will connect the serial link as soon as the communicating devices are within range of each other. Examples of possible applications are: * * * * Embedded systems Stand alone sensors Computer peripherals Domestic and industrial appliances
General Description
The F2M01SXA offers an intuitive serial cable replacement by using a wireless link, based on Bluetooth(R) technology. With its small size, long range, high voltage range and reliable data transmission, the F2M01SXA is the obvious choice for the most demanding wireless applications. No external drivers are needed, and pairing to another Bluetooth(R) device is as easy as pressing a button. Two LEDs are used to monitor the current status of the device and if any data transmission are present. The device uses a fault detection system indication if an invalid RS232 device is attached to the F2M01SXA. A user-friendly Windows application is available for configuration to suit Your requirements. The F2M01SXA can be used together with other Bluetooth(R) units supporting the Bluetooth(R) Serial Port Profile (SPP), Dial Up Networking (DUN) and HCI, e.g. Laptops, PDA and mobile phones.
(c) 2008 Free2move AB
Page 1(10)
BLUETOOTH is a trademark owned by Bluetooth SIG, Inc., U.S.A. and licensed to Free2move
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
Table of contents
1 Hardware specification..........................................................................................................3
1.1 1.2 1.3 Power supply .................................................................................................................................. 3 Power consumption ........................................................................................................................ 3 Radio performance ......................................................................................................................... 3
2
Device overview .....................................................................................................................4
2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 Green LED ...................................................................................................................................... 4 Blue LED ......................................................................................................................................... 5 Button.............................................................................................................................................. 5 D-sub............................................................................................................................................... 5 Mini-USB ......................................................................................................................................... 6 Screw .............................................................................................................................................. 6 Label ............................................................................................................................................... 6 Default configuration ....................................................................................................................... 6 Bluetooth(R) ....................................................................................................................................... 7 CE ................................................................................................................................................... 7 FCC................................................................................................................................................. 7
3
Certifications ..........................................................................................................................7
3.1 3.2 3.3
4 5
RoHS Statement.....................................................................................................................8 Ordering information .............................................................................................................9
(c) 2008 Free2move AB
Page 2(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
1 Hardware specification
Physical size: 37x17x60 (WxHxL) mm Voltage range: 5-30V DC (regulated) Current consumption (max): 300mA Temperature range: -40C to +85C Baud rate: Configurable up to 230400 baud/s
1.1
Power supply
The F2M01SXA is using external power supply and need to be powered either via pin 9 on the D-sub or the mini-USB connector. The device can be used in the voltage range of 5-30VDC (regulated, min 300mA).
1.2
Power consumption
Measured with 5V power supply at 20C and a range of 5m. (Blue LED off**)
Role Connecting Endpoint Connecting Endpoint Connecting Endpoint Connecting Endpoint Connecting Endpoint Connecting Endpoint Connecting Endpoint Connecting Endpoint Connecting Endpoint
Mode No connection No connection Connected, no data transfer Connected, no data transfer 115.2kbps full duplex 115.2kbps full duplex 115.2kbps master to slave 115.2kbps master to slave 115.2kbps slave to master 115.2kbps slave to master Connected, no data transfer Connected, no data transfer 115.2kbps full duplex 115.2kbps full duplex Connected, no data transfer Connected, no data transfer 115.2kbps full duplex 115.2kbps full duplex
Distance* Sniff mode
Short Short Short Short Short Short Short Short Long Long Long Long Short Short Short Short
Off Off Off Off Off Off Off Off Off Off Off Off 125 ms 125 ms 125 ms 125 ms
Average (mA) 48mA 10mA 12mA 27mA 42mA 46mA 38mA 39mA 37mA 42mA 19mA 18mA 50mA 52mA 10mA 10mA 11mA 12mA
Peak (mA) 86mA 63mA 58mA 95mA 138mA 160mA 167mA 215mA 131mA 164mA 207mA 207mA 209mA 215mA 189mA 150mA 153mA 142mA
*Short distance: ~5m, Long distance: ~100m **Blue LED consumes additionally ~5mA depending on the data throughput.
1.3
Radio performance
Min 2402 -8 Radio Characteristics Typ -90 Max 2480 16 Unit MHz dBm dBm
Operating Frequency Transmit Power Sensitivity at 0.1% BER
(c) 2008 Free2move AB
Page 3(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
2 Device overview
1 2 3
4
5 7 Number 1 2 3 4 5 6 7 Description Green LED Blue LED Button D-sub (DB9) Mini-USB Screw Label
6
2.1
Green LED
The green LED has different functionality depending on the current state of the device. It is possible to configure the LED indication to either be Off, On or Blinking (default). LED configuration Off On Blinking (default) Indication during state Connected HCM1 Off Off On On 1* 2*
Power up LED on for 3 sec. On On
Idle Off On On
Auto connect Off On 3*
*Indication Each square-box indicate a time slot of 100ms 1 2 3
2.1.1
Fault detection system
The F2M01SXA has a fault detection system that monitors the RS-232 signals at power up. The green LED will flash one time (independent of the LED configuration) if no valid RS-232 transceiver is connected during power up (No indication if a valid signal is present).
1
HCM - Host Controlled Mode (During configuration of the device)
(c) 2008 Free2move AB
Page 4(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
2.2
Blue LED
The blue LED indicates if there are data transmitted from and to the Plug via the connected D-sub. The indication is on as default but is possible to disable during configuration.
2.3
Button
The button has two functions depending on the current state of the device. 1. Auto connect if the button is pressed for more than 15 seconds 2. Disconnect
2.3.1
Auto connect
The Auto connect feature can be activated by pressing the button down for more than 15 seconds. The F2M01SXA will now start to search and connect to the first available remote devices supporting SPP (Serial Port Profile) in reachable distance. It can't be easier to connect two F2M01SXA to each other; simply push down the button on ONE of the device and they will try to pair. The F2M01SXA will change state to "connected" if Auto connect was successful.
2.3.2
Disconnect
It is possible to disconnect an active Bluetooth connection (State: connected) by simply pressing the button.
2.4
D-sub
The 9 pin D-sub is RS-232 compatible and support baud rates up to 230400bps. The F2M01SXA has signaling as a DCE (Data Communication Equipment) and is intended to be connected to a DTE (Data Terminal Equipment) e.g. a Computer. The F2M01SXA has hardware flow control (CTS/RTS signals) activated by default and is recommended to be used to get reliable data transmissions. It is though possible to deactivate Hardware flow control by configuration. The two extra RS-232 signals; DTR and DSR can be configured in three different modes. 1. Emulate serial handshaking lines 2. Bluetooth control - The DTR signal is used to disconnect an active Bluetooth connection and the DSR signal will indicate when you have an established Bluetooth connection. 3. Don't care. The state of the signals is not used.
5 4 3 2 1
2.4.1
Pin 1 2 3 4 5 6 7 8 9
Pinout
signal DCD TxD RxD DTR GND DSR CTS RTS Vcc Power Direction Not connected Output Input Input Ground Output Input Output Input 5-30V
9
8
7
6
Serial Port Plug connector (female)
(c) 2008 Free2move AB
Page 5(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
2.5
Mini-USB
The mini-B USB connector can be used for powering the F2M01SXA Serial Port Plug. It can also be used for high throughput data transmission when running HCI-firmware2 on the device. Mini USB Description 5 - 30V DC Data Data + Not connected Signal Ground
Pin 1 2 3 4 5
Name Vcc DD+ ID GND
Pin 1
Pin 5
2.6
Screw
The two UNC 4-40 screws can be used to affix the F2M01SXA to the host device.
2.7
Label
The bottom label is a quality mark of the product and is attached on the F2M01SXA after final testing of the device.
Article number Bluetooth Address
Technical information
2.8
Default configuration
The F2M01SXA is configured with below settings at delivery: Feature Role Security Baud rate Parity Stop bits Flow control Green LED indication Blue LED indication DTR and DSR signaling
2
Description Endpoint (slave) accepting all units to connect None 38400bit/s None 1 On Blinking On Off
HCI-firmware can be activated by configuration of the device
(c) 2008 Free2move AB
Page 6(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
3 Certifications
The F2M01SXA is certified according to CE and FCC regulations and is fully Bluetooth(R) qualified as an end product
3.1
Bluetooth(R)
F2M01SXA is fully Bluetooth(R) 2.0+EDR qualified and listed as an end product. QDID: B012540
3.2
CE
F2M01SXA complies with the requirements of R&TTE Directive 1999/5/CE, the European Community Directive 73/23/EEC and 93/68/EEC. * * * * EN 300 328 (2006-10) EN 301 489-1 (2005-09), EN 301 489-17 (2008-08) EN 62311 (2008) EN 60950 (2006)
3.3
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: * * * * Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC RF exposure compliance requirements, please follow operation instruction as documented in this manual. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC ID: R47F2M01SX
(c) 2008 Free2move AB
Page 7(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
4 RoHS Statement
The F2M01SXA Serial Port Plug meets the requirements of Directive 2002/95/EC of the European Parliament and of the Council on the Restriction of Hazardous Substance (RoHS). The device is assembled solely using RoHS compliant components.
(c) 2008 Free2move AB
Page 8(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
5 Ordering information
The F2M01SXA Serial Port Plug is available for ordering.
Part nr: Description Serial Port Plug, CD with documentation and software, USB-A to Mini-USB cable delivered in a carton (available in January 2009) Serial Port Plug, Bulk delivery
F2M01SXA-S01-C F2M01SXA-S01-B
Default settings at delivery for F2M01SXA-S01 Feature Description Role Endpoint (slave) accepting all units to connect Security None Baud rate 38400bit/s Parity None Stop bits 1 Flow control On Green LED indication Blinking Blue LED indication On DTR and DSR signaling Off
Please visit our website: www.free2move.net for more information about local distributors and dealers.
(c) 2008 Free2move AB
Page 9(10)
Rev: 2008-12-09
Serial Port Plug - F2M01SXA
Datasheet
Contact information
For support questions please contact your local dealer For more information visit our website: www.free2move.net For other purposes use: info@free2move.net
Local dealer/distributor
The information given herein includes text, drawings, illustrations and schematics that are believed to be reliable. However, Free2move makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. Free2move will in no case be liable for any incidental, indirect or consequential damages arising out of sale, resale, use or misuse of the product. Users of Free2move products should make their own evaluation to determine the suitability of each such product for the specific application.
(c) 2008 Free2move AB
Page 10(10)


▲Up To Search▲   

 
Price & Availability of F2M01SXA-S01-B

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X